| Networked Basic PDU | Single-phase, 100–240 V AC; commonly 10–32 A input | 8–24 outlets; IEC 60320 or regional socket formats | No electrical metering; network status and alarms only | No outlet switching; communication and alarm supervision | Ethernet; IPv4/IPv6, SNMP, HTTPS, email alerts | Not applicable | Basic connectivity for standard IT racks where remote outlet control is not required |
| Metered-at-Input PDU | Single-phase or three-phase; typically 16–63 A input depending on voltage and region | 12–42 outlets; vertical 0U and horizontal 1U formats | Total voltage, current, power, power factor, frequency and energy | No outlet switching; threshold alarms and load trend monitoring | Ethernet; SNMPv1/v2c/v3, HTTPS, Modbus TCP, syslog | Commonly ±1% for current and power measurements; verify the product specification | Capacity planning, branch-circuit visibility and remote environmental alarms |
| Switched PDU | Single-phase, commonly 100–240 V AC with 10–32 A input | 8–24 individually or group-switched outlets | Input current and basic load information; detailed metering varies by model | Remote on/off, outlet sequencing, power-on delays, lockout and restart scheduling | Ethernet; SNMP, HTTPS, role-based access and event notifications | Typically ±1–2% when current metering is included | Remote reboot of locked-up equipment and controlled startup of servers or network devices |
| Outlet-Level Metered and Switched PDU | Single-phase or three-phase input; commonly 16–63 A | 12–42 outlets with individual outlet identification | Input, circuit, bank and individual outlet voltage/current/power/energy, depending on model | Outlet-level switching, sequencing, current limits, scheduled control and remote reboot | Ethernet; SNMPv3, HTTPS, REST API or Modbus TCP on selected models | Often ±1% for branch and outlet metering; confirm certification and test conditions | Colocation, edge computing, chargeback and detailed device-level energy management |
| Three-Phase Intelligent PDU | Three-phase input, commonly 208/120 V, 380–415/220–240 V or 400/230 V systems | 18–42 outlets; IEC C13 and C19 combinations are common | Per-phase voltage/current, phase imbalance, total power, power factor and energy | Alarm thresholds, outlet or bank switching, load balancing support and event logging | Ethernet; SNMP, HTTPS, Modbus TCP and integration with DCIM platforms | Typically ±1% for electrical measurements, subject to the selected meter | High-density server racks, data halls and installations requiring phase-load visibility |
| Automatic Transfer PDU | Two independent single-phase sources; source voltage and current depend on the regional power system | 8–24 outlets, normally supplied from the selected source | Source A/source B voltage, current, frequency and transfer status | Automatic transfer, source priority, transfer alarms and remote status monitoring | Ethernet or serial management; SNMP and HTTPS on networked models | Measurement accuracy varies; transfer performance is normally specified in milliseconds | Single-cord equipment requiring improved source availability without dual power supplies |
| DC Intelligent PDU | Commonly 12, 24 or 48 V DC systems; current rating selected for the branch load | 6–24 DC outputs using terminal blocks, DC connectors or equipment-specific connectors | DC voltage, total current, branch current and energy on selected models | Remote branch switching, low-voltage alarms, load shedding and scheduled control | Ethernet, RS-485, SNMP or Modbus depending on the controller | Typically ±1–2%; confirm the shunt or sensor specification | Telecommunications, network edge sites, wireless infrastructure and low-voltage control cabinets |
| PDU with Environmental Monitoring | Single-phase or three-phase input; voltage and current rating selected for the rack circuit | 8–42 outlets; metering and switching may be combined | Electrical load plus temperature and humidity; optional door, leak or smoke sensors | Remote outlet control on switched versions and alarm-based operational workflows | Ethernet; SNMPv3, HTTPS, email, syslog and sensor interfaces | Temperature commonly about ±0.5 °C; humidity accuracy varies by sensor | Unmanned edge rooms, compact data centers and distributed cabinets needing local conditions monitoring |