| Distribution transformer | 6.6–11 kV | For many 11 kV systems, check equipment rated for a maximum system voltage (Um) of 12 kV. | 50 or 60 Hz, according to the power system | Select for the transformer’s maximum continuous load current; common ratings for evaluation include 250, 400, 630, and 1,000 A. | Indoor or outdoor; assess pollution, rain exposure, and solar heating. | Confirm the transformer connection, terminal arrangement, insulation level, phase-to-ground clearance, and required creepage distance. |
| Industrial or substation transformer | 11–22 kV | For many systems up to 22 kV, check equipment rated for Um of 24 kV. | 50 or 60 Hz, according to the power system | Size for maximum continuous current and any specified overload duty; commonly evaluated ratings include 400–2,000 A. | Indoor electrical room, outdoor yard, or enclosure wall; account for humidity, dust, and contamination. | Check winding connection, bushing mounting dimensions, terminal forces, temperature rise, and system insulation coordination. |
| High-voltage power transformer | 22–33 kV | For many systems up to 33 kV, check equipment rated for Um of 36 kV. | 50 or 60 Hz, according to the power system | Determine from transformer rating and winding voltage; evaluate suitable classes such as 630, 1,250, 2,000, or 3,150 A. | Often outdoor; check pollution severity, altitude, ambient temperature, and exposure to weather. | Verify power-frequency and impulse withstand requirements, external clearances, creepage distance, and mechanical loading. |
| Switchgear or busbar wall penetration | Use the switchgear or bus system voltage | Match the bushing’s rated voltage and insulation level to the assembly and system requirements. | 50 or 60 Hz, according to the power system | Match the maximum continuous bus current; common values to evaluate include 630, 1,250, 2,000, and 3,150 A. | Indoor-to-indoor or indoor-to-outdoor separation; consider enclosure sealing and the external pollution environment. | Check conductor size, mounting pattern, phase spacing, temperature rise, short-time current duty, and required clearances. |
| Outdoor installation in a polluted area | Any system voltage; select the rating for the installation | Use the required equipment voltage rating for the system, including the applicable insulation withstand levels. | 50 or 60 Hz, according to the power system | Determine from the connected equipment’s maximum continuous current and specified overload conditions. | Assess salt, industrial deposits, dust, fog, rain, and the frequency of natural or planned washing. | Select creepage distance and insulator profile for the pollution severity and site conditions; do not use voltage alone to determine creepage. |