| 1 | Confirm the full method, including sample preparation, lead collection, cupellation, and the final measurement technique. | Fire assay concentrates precious metals into a lead button, then cupellation separates the lead. The final gold result may be determined gravimetrically or by an instrumental finish, depending on the method. | Request the method description and verify that the reported result is specifically for gold, not a combined precious-metal result. |
| 2 | Check how the sample was crushed, pulverized, mixed, and split before the assay charge was taken. | Gold can be unevenly distributed, particularly when coarse particles are present. Poor sample preparation can make a small test portion unrepresentative. | Ask for the preparation procedure, the assay-charge mass, and any screen or metallics method used for suspected coarse gold. |
| 3 | Review the sample mass and the reported units and basis, such as grams per tonne or troy ounces per short ton. | Charge size and reporting basis affect how results should be interpreted and compared. Results reported on a moisture-adjusted basis are not directly interchangeable with results on an as-received basis. | Confirm the charge mass, units, and whether the result is reported on a dry-weight or as-received basis. |
| 4 | Look for duplicate assays or repeat determinations, especially for samples with visibly coarse or uneven gold. | Duplicates help reveal sampling and analytical variability. A large difference between repeats may indicate a heterogeneous sample or a preparation issue. | Ask how discrepant repeats are investigated and whether a larger or alternative test portion is used when appropriate. |
| 5 | Check whether certified reference materials with known gold values are included in the assay sequence. | Reference materials help monitor accuracy and detect analytical bias. Their certified values and acceptance limits should be appropriate to the sample grade range. | Request quality-control results for the relevant batch and confirm that control limits are established and reviewed by the laboratory. |
| 6 | Review the use of blanks and the laboratory’s procedures for preventing sample carryover or contamination. | Blanks can identify contamination introduced during preparation or analysis. They are particularly useful after samples expected to contain high gold values. | Check whether blank results are assessed against defined limits and whether failures trigger investigation and re-analysis. |
| 7 | Evaluate the complete quality-control record, including control failures, corrective actions, and any re-assays. | A reported result is more useful when the associated controls demonstrate that the analytical batch was monitored and exceptions were addressed. | Request the batch summary, review failed-control resolution, and consider independent check assays for high-value transactions or disputed results. |