| 1 | Hydrogen | H₂ | 0.0899 | 0.07 | Extremely light; rises and disperses rapidly in open areas. | A measured density above the expected value may indicate heavier impurities or incorrect temperature/pressure compensation. | Highly flammable and easily ignited. Verify purity, leak-tight packaging, cylinder pressure, and certified hazardous-gas handling. |
| 2 | Helium | He | 0.1785 | 0.14 | Very light and non-flammable; rapidly disperses upward. | Density can help screen for air, nitrogen, or other heavier-gas contamination when corrected to reference conditions. | Non-flammable but can displace oxygen in enclosed areas. Confirm purity grade, moisture limits, and fill quantity. |
| 3 | Methane | CH₄ | 0.7168 | 0.55 | Lighter than air; disperses upward in well-ventilated spaces. | Density deviations may indicate nitrogen, carbon dioxide, water vapor, or other hydrocarbon content. | Highly flammable. Check composition, methane number where relevant, water content, odorization requirements, and pressure basis. |
| 4 | Ammonia | NH₃ | 0.769 | 0.59 | Normally lighter than air at reference conditions; highly soluble in water. | Density is a screening value only; water content and concentration must be verified separately because ammonia readily absorbs moisture. | Toxic, corrosive, and flammable within a defined concentration range. Confirm container compatibility, valve condition, and safety documentation. |
| 5 | Nitrogen | N₂ | 1.2506 | 0.97 | Nearly the same density as air; movement depends strongly on ventilation and temperature. | Useful for detecting significant oxygen, argon, or hydrocarbon contamination, but density alone cannot establish high purity. | Non-flammable and chemically inert under normal conditions, but an oxygen-deficient atmosphere may develop. Verify oxygen and moisture specifications. |
| 6 | Carbon Monoxide | CO | 1.250 | 0.97 | Approximately air-neutral in density; can accumulate according to airflow and temperature. | Density is not a reliable purity test because it is close to nitrogen and air; use certified composition analysis. | Highly toxic, odorless, and flammable. Require specialized detection, documented analysis, and strict segregation from oxidizers. |
| 7 | Air | Mixture | 1.293 | 1.00 | Reference gas for relative-density comparisons. | A useful baseline for checking instrument calibration and calculating relative density; composition varies with humidity and location. | Not a substitute for certified process gas. Humidity and contaminants can change measured density and create procurement disputes. |
| 8 | Oxygen | O₂ | 1.429 | 1.105 | Slightly heavier than air; may collect in low or poorly ventilated areas. | Density can flag major dilution with nitrogen or air, but oxygen purity requires an oxygen analyzer and moisture testing. | Non-flammable but strongly supports combustion. Keep away from oil, grease, sparks, and incompatible packaging materials. |
| 9 | Propane | C₃H₈ | 1.967 | 1.52 | Heavier than air; leaked gas can accumulate in low areas and drains. | Density can help screen for excess butane, methane, nitrogen, or other LPG components; full composition analysis is required for specification compliance. | Highly flammable and heavier-than-air. Confirm odorization, vapor pressure, cylinder integrity, and transport classification. |
| 10 | Carbon Dioxide | CO₂ | 1.977 | 1.53 | Significantly heavier than air; tends to collect in pits, tanks, and enclosed spaces. | A density result outside the expected range may indicate nitrogen, oxygen, air, or hydrocarbon contamination; water content must also be checked. | Non-flammable but an asphyxiation hazard at elevated concentrations. Check purity, moisture, odor, cylinder weight, and ventilation requirements. |