| Small bathroom or toilet room | 50–80 CFM 85–136 m³/h | Ceiling-mounted exhaust fan with backdraft damper | Use a model approved for damp locations; keep electrical connections protected; verify local ventilation and wiring requirements. | Clean grille every 3–6 months; inspect duct outlet and damper annually. | Usually 0.5–2.0 sones | Approximately US$60–$180 | Approximately US$35–$120 Electricity and routine cleaning |
| Medium or large bathroom | 80–110 CFM 136–187 m³/h | High-efficiency exhaust fan with timer or humidity sensor | Confirm damp-location suitability; use a properly grounded circuit; ensure the fan exhausts outdoors rather than into an attic or wall cavity. | Clean grille and sensor every 3–6 months; inspect flexible ducting and exterior cap annually. | Usually 0.7–2.5 sones | Approximately US$90–$250 | Approximately US$45–$150 Electricity and routine cleaning |
| Kitchen cooking area | 100–400 CFM 170–680 m³/h | Range hood or cooker hood vented directly outdoors | Use a metal grease filter; maintain required clearance from cooking surfaces; follow installation rules for duct size, makeup air, and fire safety. | Wash grease filters monthly or as needed; inspect duct and exterior damper every 6–12 months. | Typically 2–6 sones, depending on speed | Approximately US$150–$800 | Approximately US$80–$300 Electricity, filter replacement, and cleaning |
| Laundry room or utility room | 70–150 CFM 119–255 m³/h | Continuous or intermittent exhaust fan with timer | Select equipment suitable for humid conditions; keep lint away from the motor; verify that the dryer exhaust is separate and not connected to the room fan. | Clean grille every 3–6 months; check for lint, moisture buildup, blocked ducting, and damper operation. | Usually 1.0–3.0 sones | Approximately US$80–$300 | Approximately US$50–$180 Electricity and cleaning |
| Workshop, garage, or storage area | 150–500 CFM 255–850 m³/h | Heavy-duty wall or ceiling exhaust fan | Use a motor and enclosure rated for the environment; avoid standard fans where flammable vapors, combustible dust, or hazardous gases may be present. | Inspect guards, blades, bearings, wiring, and exterior louvers every 3–6 months; clean dust more frequently in high-contamination areas. | Typically 3–8 sones | Approximately US$150–$700 | Approximately US$120–$500 Higher energy use and periodic servicing |
| Whole-home balanced ventilation | 80–250 CFM 136–425 m³/h | Heat-recovery or energy-recovery ventilator | Check electrical certification, frost protection, condensate drainage, filter access, duct insulation, and professional commissioning requirements. | Replace or clean filters every 3–6 months; inspect core, condensate drain, ducts, and outdoor screens annually. | Often 1–3 sones at normal operation | Approximately US$1,200–$4,000, excluding major ductwork | Approximately US$350–$1,500 Electricity, filters, and periodic service |